4 communication states, 5 wdt & bypass control logic, Communication states – ADLINK PMC-8246 User Manual

Page 17: Wdt & bypass control logic

Advertising
background image

Introduction

5

PMC-8246

1.4

Communication States

The following diagram illustrates the Normal State: where the two
GbE signals are straight-through connected to the GbE ports via
the transformers. The two GbE ports work independently as nor-
mal dual GbE ports.

Figure 1-1: Communication States: Normal

The following diagram shows the Bypass State: where the two
GbE signal are cross-over connected to each other so that the
Ethernet connection bypasses the computer or the network appli-
ance where this PMC module is installed in.

Figure 1-2: Communication States: Bypass

The relay array is driven by the relay divers which are controlled
by the watchdog timer and bypass control logic circuits.

1.5

WDT & Bypass Control Logic

The block diagram of the WDT and bypass control logic circuits is
as follows:

82546GB

Dual GbE

Trans-
former

Trans-
former

PCI-X

Bus

Relay Array

RJ-45

RJ-45

GbE #1

GbE #2

82546GB

Dual GbE

Trans-
former

Trans-
former

PCI-X

Bus

Relay Array

RJ-45

RJ-45

GbE #1

GbE #2