3 dos utilities for evaluation - utilities list, Dos utilities for evaluation - utilities list – ADLINK PMC-8246 User Manual

Page 26

Advertising
background image

14

Programming Information

The control priority is as follows. The setting with higher priority will
override the lower priority setting (or status).

3.3

DOS Utilities for Evaluation - Utilities List

Before programming this card, users can evaluate the PMC-8246
bypass capability using the DOS test utility - 8246util.exe:

8246util e [x]:

Enable the WDT. Users can determine the time out value by typing
the parameter [x]; only 1, 2, 4, or 8 is valid for [x]. If the user does
not reload the WDT before time out in 1, 2, 4 or 8 seconds
depending on the setting, then the relay array will be switched to
the Bypass State. A ‘click’ can be heard when the relay switches.

8246util d:

Disable and stop WDT. The relay array will stay in the same state.

8246util w:

Enable WDT and keep reloading WDT. The WDT would keep run-
ning unless the program stops running or powers off.

8246util n:

Enforce the relay array to Normal State and WDT will be disabled.

8246util b:

Enforce the relay array to Bypass State and WDT will be disabled.

Bypass Control Priority Control source

Reset
BYPASS state enforcement switch (SW1-2)
NORMAL state enforcement switch (SW1-3)
Bypass control mode setting MODE[0:1]

Highest



Lowest

WDT time out