ADLINK ASD26-MT1 ET Series User Manual

Page 19

Advertising
background image

Specification

19

3.1.2 Identify Device Data

The following table details the sector data returned after issuing an IDENTIFY DEVICE command.

Word

F=Fixed

V=Variable

X=Both

Default Value

Description

0

F

0040h

General configuration bit-significant

information

1

X

3FFFh

Obsolete-Number of logical cylinders (16,383)

2

V

C837h

Specific configuration

3

X

0010h

Obsolete-Number of logical heads (16)

4-5

X

0h

Retired

6

X

003Fh

Obsolete-Number of logical sectors per logical

track (63)

7-8

V

0h

Reserved for assignment by the Compact

Flash Association

9

X

0h

Retired

10-19

F

varies

Serial number (20 ASCII characters)

20-21

X

0h

Retired

22

X

0h

Obsolete

23-26

F

varies

Firmware revision (8 ASCII characters)

27-46

F

varies

Model number

47

F

8010h

7:0 – Maximum number of sectors transferred

per interrupt on multiple commands

48

F

0h

Reserved

49

F

2F00h

Capabilities

50

F

4000h

Capabilities

51-52

X

0h

Obsolete

53

F

0007h

Words 88 and 70:64 valid

54

X

3FFFh

Obsolete - Number of logical cylinders

(16,383)

55

X

0010h

Obsolete - Number of logical heads (16)

56

X

003Fh

Obsolete - Number of logical sectors per

logical track (63)

57-58

X

00FBFC10h

Obsolete

59

F

0101h

Number of sectors transferred per interrupt

on multiple commands

60-62

125,045,424

63

F

(64GB)

Total number of user addressable sectors

Advertising