Spi (bios only), Miscellaneous, Smbus – ADLINK Express-IB User Manual

Page 22

Advertising
background image

Page 22

Express-IB

3.3.10. SPI (BIOS only)

Signal

Pin # Description

I/O

PU/PD

Comment

SPI_CS#

B97

Chip select for Carrier Board SPI BIOS Flash.

O 3.3VSB

SPI_MISO

A92

Data in to module from carrier board SPI BIOS flash.

I 3.3VSB

SPI_MOSI

A95

Data out from module to carrier board SPI BIOS flash.

O 3.3VSB

SPI_CLK

A94

Clock from module to carrier board SPI BIOS flash.

O 3.3VSB

SPI_POWER

A91

Power supply for Carrier Board SPI – sourced from Module
– nominally 3.3V.
The Module shall provide a minimum of 100mA on
SPI_POWER.
Carriers shall use less than 100mA of SPI_POWER.
SPI_POWER shall only be used to power SPI devices on
the Carrier

O P 3.3VSB

BIOS_DIS0#

A34

Selection strap to determine the BIOS boot device.

I

PU 10K 3.3V

Carrier shall pull to GND
or leave no- connect.

BIOS_DIS1#

B88

Selection strap to determine the BIOS boot device.

I

PU 10K 3.3V

Carrier shall pull to GND
or leave no- connect

3.3.11. Miscellaneous

Signal

Pin #

Description

I/O

PU/PD

Comment

SPKR

B32

Output for audio enunciator, the “speaker” in PC-AT
systems

O 3.3V

WDT

B27

Output indicating that a watchdog time-out event has
occurred.

O 3.3V

THRM#

B35

Input from off-module temp sensor indicating an over-temp
situation.

I 3.3V

THERMTRIP#

A35

Active low output indicating that the CPU has entered
thermal shutdown.

O 3.3V

FAN_PWMOUT

B101

Fan speed control. Uses the Pulse Width Modulation
(PWM) technique to control the fan’s RPM.

O OD 3.3V

FAN_TACHIN11

B102

Fan tachometer input for a fan with a two pulse output.

I OD 3.3V

PU 10k 3.3V

TPM_PP11

C83

Trusted Platform Module (TPM) Physical Presence pin.
Active high. TPM chip has an internal pull down. This
signal is used to indicate Physical Presence to the TPM.

I 3.3V

PD 3.3V

If TPM not installed on
module than remove PD
3.3V

3.3.12. SMBus

Signal

Pin # Description

I/O

PU/PD

Comment

SMB_CK

B13

System Management Bus bidirectional clock line. Power
sourced through 5V standby rail and main power rails.

I/O OD 3.3VSB

PU 2k2 3.3VSB

SMB_DAT#

B14

System Management Bus bidirectional data line. Power
sourced through 5V standby rail and main power rails.

I/O OD 3.3VSB

PU 2k2 3.3VSB

SMB_ALERT#

B15

System Management Bus Alert – active low input can
be used to generate an SMI# (System Management
Interrupt) or to wake the system. Power sourced
through 5V standby rail and main power rails.

I 3.3VSB

Advertising