8.2 Direct Memory Access Channels

Channel Number

Data Width

System Resource

Comment

0

8-bits

Open

1

8-bits

Open

2

8-bits

Open

3

8-bits

Open

4

Reserved - cascade channel

5

16-bits

Open

6

16-bits

Open

7

16-bits

Open

8.3 Legacy I/O Map

Address Range (hex)

Description

000-01F

DMA controller 1, 8237A-5 equivalent

020-02D and 030-03F

Interrupt controller 1, 8259 equivalent

02E-02F

LPC SIO (Win 83627DHG) configuration index/data registers

04E-04F

TPM

040-042, 050-052

Timer, 8254-2 equivalent

060, 062, 064, 066

8742 equivalent (keyboard)

061

NMI control and status

070-077

Real Time Clock Controller( bit 7 -NMI mask)

080-091

DMA page register

092

Reset (Bit 0)/ Fast Gate A20 (Bit 1)

093-09F

DMA page registers continued

0A0-0B1 and 0B4-0BD

Interrupt controller 2, 8259 equivalent

0B2 and 0B3

APM control

0C0-0DF

DMA controller 2, 8237A-5 equivalent

0F0

Read: PCI and Master abort. (Note 1)
Write: FERR#/ IGNNE# /Interrupt controller

170-177 and 1F0-1F7

SATA controller or PCI

376 and 3F6
2F8

COM2

3F8

COM1

4D0 and 4D1

Interrupt controller

CF9

Reset Control register (8 bit I/O)

4700

TPM

E000-E03F

Graphics

E040-E05F

SMbus

E060-E07F

82579Lan

E080-E137

SATA

E140-E147

Remote Keyboard and Text (KT)(When iAMT support)