JP1:

AT/ATX MODE

In AT mode, JPY1 shorts PS_ON# to ground
directly to force power on. See 8.6 AT Power
Mode
on p. 38.

Jumper

Status

1-2

ATX Mode

<<<<

2-3

AT Mode

1
2
3

CN2:

PWR_OK Config

Jumper

Status

1-2

Add 3.3V Pullup with 10K to signal PWR_OK

3-4

Connect PWRGOOD of ATX power supply

<<<<

5-6

Connect PWRGOOD of onboard DCDC regulator

Note:

<<<< indicates default setting

6.18 Power Jumper Settings

JP2:

PS_ON# Signal Source

Jumper

Status

1-2

SUS_S3#

<<<<

2-3

SUS_S5#

1
2
3

All ADLINK modules support S3 mode and
consecutive power down of ATX power supply.
For modules that connect the S3 signal, PS_ON#
should always be set to SUS_S3# as source (even when S3 mode is disabled in the BIOS). For
modules that do not bring out the S3 signal, PS_ON# should be set to SUS_S5# as source.

JP3:

AT Power 5V Setting

With an AT power supply is connected to
the Express-BASE6, JP3 can be used to
provide 5VSB to the COM module from
the carrier board.

Jumper

Status

1-2

AT without P5V

<<<<

2-3

AT with P5V

1
2
3

JP3: 5VSB to Module Source

Jumper

Status

1-2

5VSB produced on
carrier from Vcc

2-3

5VSB from ATX power
supply

3-4

No 5VSB from module