Gpo_write(), Gpo_read() – ADLINK MXE-200i User Manual

Page 51

Advertising
background image

Watchdog Timer (WDT) & DI/O Function Libraries

37

MXE-200

Returns the digital logic state of MXE-200 digital input channels
1 to 8 (bit 0 to 7)

@ Return code

NoError

ErrorOpenDriverFailed

ErrorDeviceIoctl

GPO_Write()

Sets the digital logic state of the digital output line.

@ Syntax

C/C++

I16 GPO_Write(U16 wState)

@ Parameters

State

Sets the digital logic state of MXE-200 digital output channels 1
to 8 (bit 0 to 7) to 0 or 1.

@ Return code

NoError

ErrorOpenDriverFailed

ErrorDeviceIoctl

GPO_Read()

Reads the digital logic state of the digital output line.

@ Syntax

C/C++

I16 GPO_Read(U16 *pwState)

@ Parameters

pwState

Returns the digital logic state of MXE-200 digital output chan-
nels 1 to 8 (bit 0 to 7).

@ Return code