ADLINK NuPRO-A40H User Manual

Page 68

Advertising
background image

54

BIOS Setup

Terminal Type

VT-UTF8 is the preferred terminal type for out-of-band man-
agement. The next best choice is VT100+ and then VT100.
See above, in Console Redirection Settings page, for more
Help with Terminal Type/Emulation. Options: VT100, VT100+,
VT-UTF8, ASNI.

Bits per second

Select the bits per second you want the serial port to use for
console redirection. The options are 115200, 57600, 38400,
19200, 9600.

Flow Control

Set this option to select Flow Control for console redirection.
The settings for this value are None, Hardware RTS/CTS.

Data Bits

Displays the frame width for Out-of-Band Management.

Parity

Displays the parity for Out-of-Band Management.

Stop Bits

Displays the number of stop bits for Out-of-Band Management.