Operating temperatures, Environmental, Operating systems – ADLINK AmITX-BT-I User Manual

Page 10: Power consumption

Advertising
background image

Page 10

AmITX-BT-I

2.11. Operating Temperatures

¾

Standard:

0°C to 60°C

¾

Extreme Rugged™:

-40°C to 85°C* (optional)

*Note: Intel® Atom™ E3800 Series processors only

2.12. Environmental

¾

Humidity:

10-90% RH operating, non-condensing

5-95% RH storage (and operating with conformal coating)

¾

Shock and Vibration:

IEC 60068-2-64 and IEC-60068-2-27

MIL-STD-202F, Method 213B, Table 213-I, Condition A and Method 214A, Table 214-I, Condition D

¾

HALT: Thermal Stress, Vibration Stress, Thermal Shock and Combined Test

2.13. Operating Systems

¾

Standard Support:

Windows 7/8 32/64-bit, Linux 32/64-bit

¾

Extended Support (BSP):

WES7, WE8S, WEC7, Linux, VxWorks

2.14. Power Consumption

System Configuration

Processor

Intel® Atom™ Processor E3845 (2M Cache, 1.91 GHz)

Memory Slot1

Transcend 8G 2Rx8 DDR3L 1600 SODIMM

Memory Slot2

Transcend 8G 2Rx8 DDR3L 1600 SODIMM

Graphics

Intel® HD Graphics

Storage

WD WD3200BUDT 320GB, 2.5" SATA 3Gb/s HDD

Monitor BenQ

GW2255

Power Supply

FSP FSP350-60PFG 350W ATX

Video Resolution

1920 x 1080 @32-bit

¾

Intel® Atom™ processor E3845 @ 1.91 GHz

Power State

Current(A) / Voltage (V)

Power (W)

Windows 7 (Idle)

0.61/11.82

7.2102

Windows 7 (Typical)

0.92/11.78

10.8376

Windows 7 (Max loading)

1.08/11.77

12.7116

S3 0.3/5.02

1.506

Advertising