EN

ENGLISH

-6-

Clarke

®

American Sanders

Operator's Manual (EN) - Floorcrafter

Figure 1

230V Electrical Connection Instructions

CAUTION: This machine will operate only on AC fre-

quency and on electrical voltage shown on

the equipment nameplate. Make sure you

have the correct frequency and voltage be-

fore connecting the power cord to an out-

let. See the example in figure 1.

This machine must be connected to an electrical source with an

earthing conductor in order to protect the operator from electric

shock. This machine has an approved power cord with three con-

ductors as well as a plug with three terminals. Connect the plug to

a matching receptacle.

DANGER: Electrocution could occur if the machine

is exposed to water or rain. Keep the ma-

chine in a dry building.

DANGER: Electrocution could occur if machine is not

connected to an electrical source with an

earthing conductor. To prevent possible

electric shock, use an electrical cord with

an earthing conductor and connect it to a

matching electrical source. For maximum

protection against electrical shock, use a

circuit that is protected by a ground fault

circuit interrupter. Consult your electrical

contractor.

DANGER: Electrocution could occur if the machine is

used with a damaged plug or power cord.

If the cords or plugs are worn or damaged

in any way, have them replaced by an au-

thorized service person or electrician.

Extension Cords

Use only an approved three-pronged extension cord with two main

conductors and one earthing conductor. This machine is equipped

with a power cord. When greater range is needed follow the table

below to determine cable gauge of additional footage. Refer to the

chart to the right for extension cord information.

If motor appears to labor or takes a considerable longer time to

come up to speed reduce sanding pressure.

Feet/Wire Gauge (Stranded Copper)

Source Voltage

0 - 100’

100 - 250’

208

6

Use Voltage Booster

230

10

8

Advertising