Control setup, Before starting, Installation – Bonaire 3 Star Mid Efficiency User Manual

Page 10: Manual thermostat - pne, Programmable thermostat, Ontrol, Etup, Control setup c

Advertising
background image

3

S

TAR

M

ID

E

FFICIENCY

D

UCTED

G

AS

H

EATER

.



Page 10

Control Setup

C

Control Setup

Before Starting
Before attempting to use the setup instructions for the controls system, make sure the low voltage
cable is connected and the 240 volt power has been turned on to the heater / cooler.

I

NSTALLATION

The thermostat must be installed approximately
1.5 metres above the floor level on a room wall
which is most commonly used for best average
sensing.

Do not locate control near concealed hot or cold
water pipes, warm air ducts, radiators, sunlight,
or draughts from hallways, stairways or
fireplaces and seal against draughts through
wall cavities. These can all affect the correct
temperature sensing.

Manual Thermostat - PNE

Installation – Fix the mounting plate to the wall.

Connection – connect the 2 wires to the fly leads on

the wall control board. Once the correct polarity has
been established, use the crimp connectors to
secure the connection. Place connectors in the wall
cavity.
Note – POLARITY of the 2 wires is important. If
the polarity is incorrect the unit will start
immediately without instruction from the control.

Once the wiring connection has been made snap the
control onto the mounting plate.

Temperature Calibration – The thermostat comes

pre-calibrated from the manufacturer. However,
should the thermostat require re-calibrating, use the
following procedure.

STEP 1

Remove the control from the mounting panel.

STEP 2

Turn the control ON.

STEP 3

Turn the control OFF holding the ON/OFF button down until all icons are displayed
in the control and release.

STEP 4

Wait 10 seconds for the control to complete the auto code. Turn control ON.

STEP 5

On the control board adjust the ROOM TEMP by rotating the thermostat calibration
knob.
There is only 10 seconds available to adjust the temperate indicated by the ROOM
TEMP value flashing. To further adjust repeat steps 3, 4 and 5.

STEP 6

Replace the thermostat to the mounting base.

Programmable Thermostat

Refer to the installation details provided with the thermostat.

Advertising