Installation, Installation requirements, Unpacking the unit – Bonaire Durango Window Cooler User Manual

Page 8: Warning

Advertising
background image

B

ONAIRE

D

URANGO

W

INDOW

C

OOLER

Installation

Installation

I

NSTALLATION

R

EQUIREMENTS

Tools

Materials Required (Not supplied)

-

Drill (Power or Cordless)

-

Silicone for sealing Window Infill
Panel

- Adjustable

Wrench.

-

Copper or plastic high pressure
water pipe for mains water supply.

-

Phillips Head Screw Driver

-

Drill bits for drilling pilot holes into
window frame. 1/8" (3.2mm) drill or
appropriate for size of screw used.

-

840mm (33”) of suitable spacer
material (if required)

-

¾” Philips Head Screws for affixing
Window Infill Panel

U

NPACKING THE

U

NIT

Warning

When you receive your unit the fan assembly will be partially located inside the
wet section of the product.

Before installing the product in the window the telescopic section of the
unit

MUST

be fixed in place.

Step 1

Pull the fan assembly out of the unit by
approximately 6” (150mm) until it hits
the wet box wall.

Step 2

Fix the fan assembly into place using
the 12 pozi-drive screws supplied.

Ensure the screws are done up tight so
there is no vibration between the fan
housing and the wet box.

WEAC628

The unit is now ready for installing into your
window.