Refer ence man ual, Wir eless fuzzyscan, Symbology reading control – Cino PL680BT HC User Manual

Page 41

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

33

PROGRAM

Symbology Reading Control

UPC-A & UPC-E Setting

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

UPC Supplement Setting

SS
SS
SS
SS
SS
SS
SS
SS

Select UPC without supplement digits
Select UPC with only 2 supplement digits
Select UPC with only 5 supplement digits
Select UPC with 2/5 supplement digits
Disable force supplement digits output
Enable force supplement digits output
UPC Family Addenda Separator Off
UPC Family Addenda Separator On

0
1
2
3
4
5
6
7

UPC/EAN Security Level

SS
SS
SS

Level 0
Level 1
Level 2

Only available for UPC-A & EAN-13

0
1
2

Supplement Scan Voting

SS
SS
SS
SS
SS
SS
SS

None
Level 1
Level 2
Level 3

Level 4
Level 5
Level 6

Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13

0
1
2
3
4
5
6

7
8
9

A
B
C
D

UPC/EAN Security Level

The scanner offers three levels of decode security for UPC/EAN bar codes:

Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this

security level may significantly impair the decoding ability of the scanner.

Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may

increase the misread.

The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding

a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5

supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,

low contrast or damage barcode labels.