Refer ence man ual, Wir eless fuzzyscan – Cino PL680BT HC User Manual

Page 88

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

80

PROGRAM

Operation Control

(All Series)

Out-of-range Scanning, Link Supervision Time-out

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

Out-of-range Scanning

SS
SS

Disable
Enable

0
1

Link Supervision Time-out

SS
SS
SS
SS
SS

1 sec
3 secs
5 secs
7 secs
9 secs
Only available in PAIR & PICO modes

0
1
2
3
4

Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode
data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to
continue scanning barcode data into memory buffer until radio link resumed.

The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.

.

Advertising