Refer ence man ual, Wir eless fuzzyscan, Serial interface control – Cino PL680BT HC User Manual

Page 67

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

59

PROGRAM

Serial Interface Control

Record Suffix, Preamble ,Postamble Setting

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

STX/ETX Control

SS
SS

Disable STX/ETX transmission
Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total
data frame transmitted via serial interface.

0
1

Record Suffix

SS
SS
SS
SS
SS
SS

MS

None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
SPACE (20H)
User defined character (1 character)

0
1
2
3
4
5

6, (00-7F)

Preamble

SS

MS

None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.

FIN

[00-7F], [FIN]

Postamble

SS

MS

None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.

FIN

[00-7F], [FIN]

FNC1 Symbol Char. Transmit

SS
SS

Disable
Enable

When this function is enabled and the FNC1 is contained in scanned data, the
scanner transmits the FNC1 to the host. Chart of the FNC1 is provided in Appendix –
Keyboard Function Code Table. When the scanner interface is set to keyboard, the
scan code is converted to corresponding key function before it is transmitted

0
1

Serial Interface Message String (RS232, USB COM) :

STX

Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble ETX Record

Suffix

1 character

1-15 characters

2-4 digits

1 or 3 characters

Variable length

1 or 3 characters 1-15 characters

1 character

1 character

Advertising
This manual is related to the following products: