Replacing the Wave Bearings

Over time, the four plastic wave bearings (#13630)

may become worn. Follow these instructions to replace

the wave bearings:

1.) Remove any primers from the primer system by

removing the primer magazine tube (*#13879). Store live

primers safely!

2.) Remove the three screws (#13989) that attach the

primer system (*#20253 - see pg. 6) to the machine.

3.) Remove the primer system from the machine.
4.) Disconnect the failsafe rod (#16814) by unclipping

it at the powder measure bellcrank.

5.) Remove the index bolt (#13461), located at the

back of the frame below the mounting surface. It may be

necessary to remove the machine from the bench to

access this bolt.

6.) Remove the four screws (#13896) which hold the

link arms (#13822) to the frame.

7.) Support the shaft (#13437) with one hand and

remove the link arms.

8.) Withdraw the shaft from the bottom of the frame

(#13445).

9.) Now the four wave bearings can be removed from

the inside of the frame and the replacements fitted.

10.) Reassembly is the reverse of the above procedure.

Square Deal “B” Conversion Instructions

Changing calibers on your SDB is a simple procedure.
First, you must decide whether you need to change the

priming system that is now set up on your machine. Small

calibers use small pistol primers and large calibers use

large pistol primers. Skip step one if there are no primer

size changes.

Step 1: Changing The Priming System

Remove Primer Early Warning System. Remove three

screws (#13989 – refer to schematic) to remove the

primer system from the front of the machine. Remove the

primer slide return spring from pin (#13790) and remove

the primer slide assembly from the magazine system.

Replace the correct size primer slide in the same manner.

IMPORTANT Make sure the magazine is empty of all

primers by inverting the primer assembly.

Remove cap (#13957) and pull out the internal

magazine tube (#13673). Take the correct size magazine

tube and drop a primer, anvil side up, into the top of the

tube to make sure the primer drops freely through the

tube and orifice. Insert the magazine tube (#13673) into

the magazine shield with the keyed side of the orifice

pushed all the way down into the notch or key way in the

housing (#20900). Replace the cap (#13957). Do not over

tighten!

Now, insert a few primers, anvil side up, into the

magazine. Pull the handle, a full stroke, raise the handle

and a primer should appear at Station 2. If a primer fails

to appear, adjust the primer feed adjustment screw

(#13961a), located at the lower tip of the flat spring

(#13979) on the front of the housing (#20900) as follows:

If changing from a large primer to a small primer turn

the primer feed adjustment screw (#13961a) in 1/8 turn

increments clockwise. If changing from small to large,

turn in 1/8 turn increments counterclockwise.

Cycle the handle again and a primer should appear. If

the primer cup is not centered under the shellplate or

snaps into place when the handle is raised it may be

necessary to adjust the primer slide travel by turning the

slide stop adjustment screw (#13961b) in 1/8 turn

increments. It is located between the primer slide and the

coiled spring (#13798) on the front on the housing. (see

pgs 3 & 4.)

Step 2: Changing Shellplates

Lift out the ejector wire (#13433) and remove the

shellplate bolt (#13328). Carefully remove the shellplate

and be aware of a very small index ball (#14019) that sits

on a spring. Install the correct shellplate.

The short end of the ejector wire fits behind the

shellplate bolt (#13328). Note: The correct positioning of

the ejector wire is important or serious damage to the

sizing die could result. See Fig. 6.

Step 3: Changing and Adjusting Dies

Use of Dillon’s Bench Wrench is suggested when

changing or adjusting dies.

Remove screw (#13895) and remove the powder

measure. Remove screws (#13815) and (#14037) and

remove the toolhead assembly. Lift out the three die

inserts (#12864, #11628, #11734) from the frame. Note:

The toolhead you just removed is adjusted for those dies.

Store these parts for when you set up this caliber again.

Now, take the dies of the caliber that you are

converting to and insert them into the frame,

corresponding to the position reference number on each

die. 1, 3 & 4. If you choose to use the toolhead you

removed, be certain that you back out the adjustment bolt

(#13908) at Station 4 and remove the seating stem at

Station 3.

12

Fig. 18