IP024-027 RevA

MFD-100 Lift Series Installation

4/3/2007

Figure B


4.)

Determine the microphone location and signal pathway and drill a hole in the top plate large enough

to accommodate all the required cabling. Removing the connector on the microphone cable will
allow for a smaller hole.

For a more seamless appearance, have the mill worker attach a matching piece of wood or veneer
from the table to the top plate. Another wood surface may be attached in the same manner to the
plate in the “down” position as well. ½” is the maximum recommended cover thickness. Use
magnetic tape to hold the decorative table surface to the Top Plate. Do not permanently attach the
wood to the plate until instructed to do so.

REMEMBER: MOST TABLE MICROPHONES NEED TO BE AT TABLE TOP HEIGHT TO WORK CORRECTLY!

Figure C

5.)

Run the necessary wiring from the microphone/speaker through the newly-drilled hole(s), through

the triangular pivot, and out the side of the unit.

6.)

Use magnetic tape, double-stick tape, or a similar product to attach the microphone/speaker to the

top plate or wood surface. Depending on the equipment you are using, it might be easier to
connect the wiring before attaching the microphone or speaker. Then, reattach the top plate to the
assembly. If you are adding a matching table surface, make sure there is enough clearance to allow
the device to rotate fully. Once you have verified this, attach the table surface to the plate.