RT80Q Operator’s Manual

Service - 163

500 Hour

Plow

Change Plow Vibrator Oil

Change plow vibrator oil every 500 hours. If
normal operating temperature exceeds 100° F
(38° C), change plow vibrator oil every 250 hours.

Drain oil at drain plug (2). Replace plug and move
plow vibrator to horizontal position. Add MPL at
fill (1).

Add oil until level is at halfway point on sight glass

(1).

Refill capacity is 4 qt (3.8 L).

IMPORTANT: Do not drain oil from plow
vibrator when hot. Let plow vibrator cool
before removing drain plug.

t33om078w.eps

1

2

t33om077w.eps