221906B

To relight the main burner turn control thermistor knob “A”
clockwise to the desired setting between the minimum, "O" and
maximum position.

For longer periods, turn the control thermistor knob “A” to
“Reset” position. Switch off the electrical supply to the boiler.

To relight follow the full lighting instructions given above.

Lighting the fire

Please note:

When operating your fire for the first time, some vapours may
be given off which may cause a slight odour and could possibly
set off any smoke alarms in the immediate vicinity. These
vapours are quite normal with new appliances. They are totally
harmless and will disappear after a few hours.

To light the fire

The control is shown in diagram 4.

Depress the control knob and turn partially to the 1/IGN position
until you feel some resistance.

Keep the knob depressed at this position for a few seconds to
allow gas to flow to the burner.

While keeping the knob depressed, turn to the 1/IGN position.
While turning, a spark should light the pilot.

Keep the knob depressed at the 1/IGN position for a further 10
seconds then release it. The centre section of the coal will be
alight at this position.

Depress the control knob slightly and turn it to your desired
burner setting.

The control knob should be depressed slightly before turning
whenever you are changing the burner setting.

The burner settings are ;

1/IGN.............Centre section on low. Outer sections off.

2.................... Centre section fully on. Outer sections off.

3.................... Centre section fully on. Outer sections on low.

4.................... Centre section fully on. Outer sections fully on.

We recommend that the fire is set at position 4 for the first 10
minutes after lighting to warm up the chimney and so obtain full
efficiency quickly.

If operating the appliance for long periods it is beneficial
occasionally to change the settings. This will also help to
remove any carbon deposits that may form during operation.

Note: If the fire goes out while setting the control, repeat the full
lighting procedure. If the fire repeatedly goes out, have the fire
serviced.

To turn the fire off

Partially depress the control knob and turn clockwise to OFF.
Release the knob.

Wait at least 3 minutes after turning the fire off before relighting.

Lighting with a taper

In the unlikely event of failure of the ignition spark, the pilot can
be lit with a long taper or spill after the glass panel surround has
been removed. Removal of the surround is descibed in the
"Glass Panel" section.

Light the pilot by inserting the taper or spill below the centre of
the glass panel assembly while the control is kept depressed
at the 1/IGN position, see diagram 6.

When the pilot has lit follow the rest of the instructions in the
section headed "To light the fire".

Metal Parts

Clean the metal parts with a slightly damp cloth and then dry.

Do not use abrasive cleaners as these will scratch the fire
surface.

Diagram 5

9509

GLASS
PANEL
SURROUND

Diagram 4

9485

Instructions for Use

9488

GLASS PANEL
ASSEMBLY

Diagram 6

9705

Advertising