Operation – Glow-worm Clearly Heat Recovery User Manual

Page 11

Advertising
background image

www.glow-worm.co.uk

11

Operation

Bypass (optional)

The Atmosorb can be equipped with a bypass, which is fitted

on the top of the device, see diagram 2.
With a bypass installed the user may operate the so-called

"free cooling mode" during the summer months with the

outside temperature falling below room temperature during

the night. The cooler outside temperature will not be warmed

by the device before it was blown into the room. To protect

the bypass valve from dirt, we recommend an outside air

filter of the filter class at least G3. The filter is installed on site

into the outside air duct, possibly close to the air inlet.

Switching on and off

The Atmosorb is supplied with electrical power via a 230 V

mains line.
• Insert the mains plug into the 230-V socket.

The electronics of the ventilation appliance is starting. The

display shows the unit type (display "275 or 350") and then,

after about 3 seconds, the indication switches to the basic

display.
• To switch off the unit, pull the mains plug out of the plug

socket. Using the "off" menu point on the remote control

switches the unit to the lowest fan speed. To set the remote

control to the off position, press "mode" and then the "+"

button until "off" is displayed.

Functional Overview of the Digital Remote

Control

The Atmosorb is equipped with a digital remote control to

operate the unit.

The remote control allows you to set various operating

programs. In addition, you can set special functions as well

as a time-controlled function of the ventilation unit, please

see the "User Controls" section.