Cleaning the Filters

Continued efficient operation, reliability and a long service life

as well as safety, require inspections and maintenance work

to be regularly carried out by a

competent person approved

at the time by the Health and Safety Executive and on an

annual basis.
We recommend making a maintenance agreement. The

operational reliability of the device can be impaired, resulting

in damage to property or personal injury, if maintenance work

is not carried out.
You, as the owner or user, may execute the following

maintenance work yourself:
– Clean and replace the filters in the domestic ventilation unit.
– Clean and replace the filter in the bypass casing (if used).
– Clean the fresh air or exhaust air valves in the living space.
– Reset the time interval for filter replacement in accordance

with section "User Controls"
It depends on the contamination levels how often the filters

must be cleaned or replaced. We recommend to regularly

check the filters during the initial operational period and

assess the need to clean them, e.g. every three months. If

you then feel that the filters are only slightly contaminated or

dirty, you may extend the interval.
NOTE: Replace the filters at least once a year or after a

maximum of 2000 operating hours.
You can clean the filters with a vacuum cleaner. If this is not

enough, the filters must be replaced.
DO NOT clean the filters with water or other liquids.
Dispose of the used filters with the domestic waste.

Cleaning or Replacing the Filter

To check and clean the filters, please proceed as follows:
● Unplug the Atmosorb from the mains.
● Pull the filter out of the unit.
● Remove the filter handles from the filters.
NOTE: Before inserting the filters, please ensure the correct

positioning in order to avoid damaging the filters.
● Position the filter handles on the clean or new filters.
On the one side, the filter handles are fitted with guides which

must be pushed into the grooves in the unit.
– The upper filter of the Atmosorb and the bypass filter are

mounted with these guides pointing to the bottom.
– The lower filter is mounted with the guide pointing to the top.
● Push the filters back into the unit.

To operate, plug the mains plug back into its socket

.

There are fine filters available as well as the standard filters:

Description

Filter class Ordering number

Filter set

G3

0020023930

Filter Bypass

G3

0020023931

Fine filter set

F6

0020026061

Fine filter Bypass

F6

0020026118

If you intend to use these filters, please contact an expert

technician.