User controls – Glow-worm Clearly Heat Recovery User Manual

Page 14

Advertising
background image

www.glow-worm.co.uk

14

User Controls

Automatic operation:

The change between the day and night operation

occurs automatically. Additionally, the current

operating mode is displayed.

Minimum operation:

Irrespective of the time programme the remote

control switches the fans into the lowest stage.

Press "mode" twice.
Fan stage 3

Display shows: HIGH

.

Press

- or + in order to set the period of time. The 3rd fan

stage is active at this time. You can have a 0 to 24 hrs boost,

use the

- or + buttons to set.

To deactivate this function, set the period of time to "0.0".

Press "mode" three times.
Bypass in stand-by
Display shows: COOL

If the bypass unit is not fitted, this menu point will not show.
Press

- or + to set the number of days between 0 and 60,

during which the bypass shall be in stand-by mode. Under

the correct temperature conditions the bypass engine

switches to summer mode.

Check and setting of the time
Press "mode" several times in order to select days of the

week, hours and minutes as required. The selected category

flashes in the display.
Press

- or + to change days of the week, hours and minutes.


Check and reset of the filter timer
Press "mode" six times.
Display shows: FILT
The timer indicates the number of days after the last reset

since the filter has been used.

Press "mode"
Return to basic display
If no new setting is executed for more than 10 seconds, the

display will automatically return to the basic display.

Advertising