Installation, 6 appliance location – Glow-worm Clearly Heat Pumps 5kW User Manual

Page 12

Advertising
background image

0020096879_01 - 06/10 - Glow-worm

- 10 -

INSTALLATION

INSTALLATION

i

All the drawings dimensions are shown in mm.

6 Appliance location

6.1

Location

6.1.1

Instructions

• Before choosing a site for the appliance, carefully read the

safety warnings and installation manual.

• Ensure that the wall to which the appliance will be mounted

on is structurally safe in order to support the weight of the

appliance.

• Ensure there is sufficient space available for the appliance,

taking care that minimum clearances are adhered to ensure

that the connections to the water, gas and flue can be

accessed and inspected (see chapter Clearances).

• Observe current regulations.

• Install the appliance outside.

• Do not install the appliance:

- near a heat source,

- near flammable materials,

- near the ventilation points of adjacent buildings

- beneath deciduous trees.

• Take into account the following when installing the heat

pump:

- prevailing winds,

- the noise generated by the fan and the compressor

- the visual impact on the surrounding neighbourhood.

• Avoid areas exposed to strong winds directed against the

appliance’s air outlet.

• Set the appliance on one of the following supports:

- concrete slabs,

- crane beam,

- concrete blocks.

• Do not install the fan facing the nearby windows. If

necessary, install a noise barrier.

• To avoid transmission of vibrations to the surrounding

buildings:

- use hoses for water connections,

- install the anti-vibration pads supplied with the appliance.

• Ensure that the appliance is protected from water and from

snow.

• Do not expose the heat pump to corrosive or dusty

atmospheres (near to dirt roads, for example).

• Do not place near to stale air extraction fans.

• Allow room for electricity cables (high and low voltage).

• Explain these requirements to the appliance user.

6.1.2

Discharge of condensates

A

B

B

A

1%<α<2%

B

A

1%<α<2%

• Depending on the gradient, install the condensate discharge

bend at the lowest point and the cap at the highest point.

• Make allowance for a condensate discharge circuit.

6.1.3

Regulations

• Please ensure that all correct permissions have been

obtained from the local planning office, prior to siting the

appliance.