INSTALLATION

9 Hydraulic connection

• Take care to clean the pipes before assembly removing any

debris or burrs. Grease and oils may need to be removed

they are not possible to remove by cleansing and flushing.

Foreign bodies in the system may enter the appliance and

interrupt its operation.

• Do not use any solvent products, due to the risk of damaging

the circuit.

• Only use original seals supplied with the appliance.

b

Make sure that mechanical connections are not

overtightened.

1

2

3

2

3

Key

1 Cap

2 Return connection (Ø1 ") to the heat pump

3 Heat pump flow connection (Ø1 ") to the building

• Remove the protective caps (1) from the heat pump

connections.

• Install the filter on the heat pump return pipe. Install it

between 2 shut-off valves in order to be able to remove if

from the circuit and clean it periodically.

• Install outgoing and return heat pump pipes in the direction

of the hydraulic module.

Linear distance (without elbows or

additional pressure drops)

Min. diameter of pipe to

be installed

≤ 20 m

Ø ¾"

≤ 30 m

Ø 1"

• Check that there are no leaks. Repair if necessary.

• Insulate all exposed pipework.

10 Evacuation of condensates

When the appliance is operational, it will produce condensation

that needs to be drained off.

1

2

3

A

1

3

2

B

Key

A Configuration with inclination to the left

b Configuration with inclination to the right

1 Heat pump

2 Plug

3 Drainage elbow

• Insert the drainage elbow (3) and pipe into the correct

opening depending on the angle of the heat pump.

• Seal off the other opening with the supplied plug (2).

11 Electrical connections

e

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of

the appliance must be made only by a qualified

engineer.

The appliance must be connected directly to an accessible,

fixed, switched, electrical outlet.