5 commissioning, 20 installer menu, 1 setting the system parameters – Glow-worm Clearly Solar System User Manual

Page 20

Advertising
background image

20

Installer menu

Access the installer menu by pressing the

button for 3

seconds.

Press the

button for 3 seconds again to return to the

operating menu.

These parameters should only be adjusted by the installation
engineer.

5.1 Setting the system parameters

Certain system parameters have to be set in order to optimise

the system for the respective conditions. These parameters are

all together in the installer menu and should only be set by the

installation engineer.

Access the installer menu.

Display

Press + or - to adjust

Press PROG to accept

Setting range

Factory setting

Changing the hydraulic plan

1. 1 collector array.

2. 2 collector arrays (East/West system).

3. Not used.

1, 2, 3

1

Setting the flow rate

When setting the the required flow rate,

please observe the measurement units,

required for display of Solar gain.

0 – 165 litres/min

0

Resetting the solar gain.

The solar gain is reset to 0 by turning the dial

to 1.

-

-

Resetting the operating hours.

The operating hours are reset to 0 by turning

the dial to 1.

-

-

Setting the max. temperature for cylinder 1

20 to 90 °C

75 °C

Setting the activation difference for cylinder 1.

(The activation difference should always be 2

K greater than the deactivation difference)

2 – 15 K

7 K

Setting the deactivation difference for cylinder

1.

(The deactivation difference should always be

2 K less than the activation difference)

1 – 10 K

3 K

IMPORTANT:

l

The hydraulic plan, flow rate and current date must be

entered.

l

It is also recommended that the solar gain modulation and

cylinder reheat delay are activated.

l

Ask the householder how long they normally program the

DHW to be on for before they actually require it. If one hour or

more, activate the cylinder reheat delay.

l

It may not be necessary to change any other settings from

the factory defaults

Exit the installer menu.

The following table gives an overview of all system parameters

and their factory settings and range.

5 Commissioning

Advertising