Warnings, 4regulations, Electrical supply – Glow-worm Clearly Solar System User Manual

Page 4: Testing and certification, Ce mark, Benchmark scheme, Safety instructions

Advertising
background image

4

Regulations

When installing and commissioning the system, the current

version of regulations below shall be observed.

The electrical installation must be installed by a

competent

person and in accordance with the relevant standards

Electrical Supply

The product MUST be earthed.

All system components shall be of an approved type and all

wiring to current I.E.E. wiring regulations.

External wiring must be correctly earthed, polarised and in

accordance with the relevant standards.

In GB, this is BS 7671.

In IE, this is the current edition of ETCI rules.

The product MUST be connected to a permanent 230V ac,

50Hz supply.

Connection of the whole electrical system of the product,

including any heating controls, to the electrical supply MUST

be through one common isolator and must be fused 3 Amp

maximum.

Isolation should be by a double pole switched fused spur box,

with a minimum gap of 3mm for both poles. The fused spur

box should be readily accessible and preferably adjacent to

the product. It should be identified as to its use.

Alternatively connection can be made through an unswitched

shuttered socket and 3A fused 3-pin plug both to the current

issue of BS 1363, provided they are not used in a room

containing a bath or shower.

Wiring to the product must be PVC 85°C insulated cable, not

less than 0.75mm2 (24/0.20mm).

Testing and Certification

This product is tested and certificated for safety and

performance. It is, therefore, important that no alteration is

made to the product, without permission, in writing, by Glow-

worm.

Any alteration not approved by Glow-worm, could invalidate

the certification, warranty and may also infringe the current

issue of the statutory requirements.

WARNINGS

SAFETY

The fluropro must be installed by a competent person, who is responsible for adhering to

the existing standards and regulations.

ALTERATIONS

Under no circumstances should you ever attempt to make alterations to these

components or any other part of the system

SEALED COMPONENTS

Under no circumstances must the user interfere with or adjust sealed parts.

IMPORTANT

Danger of death by electric shock! All live parts of the system may be installed, serviced and repaired

only by a qualified servicing company!

Risk of overvoltage! Earth the solar circuit as potential equalisation and protection against

overvoltage! Attach earthing pipe clips to the solar circuit pipes and connect the clips to a potential

rail with a 16mm

2

copper cable.

CE Mark

The CE mark on the Fluropro solar control indicates that

it complies with the basic requirements of the applicable

directives as stated on the data badge.

“Benchmark scheme”

Glow-worm support the Benchmark initiative. It is very

important that the service record is completed by the

installation engineer and handed over to the user.

Safety Instructions

The entire solar system must always be installed and

operated in accordance with recognised technical standards.

IMPORTANT: Danger of death by electric shock! All live parts

of the system may be installed, serviced and repaired only by

a qualified servicing company!

IMPORTANT: Risk of overvoltage! Earth the solar circuit as

potential equalisation and protection against overvoltage!

Attach earthing pipe clips to the solar circuit pipes and

connect the clips to a potential rail with a 16mm

2

copper cable.

Advertising