23

Adjust the solar water heating target tem-

perature setting

Important: Set the solar water heating target temperature to

the maximum adjustment

Press and hold the

button to increase the solar water

heating target temperature, or press and hold the

button

to decrease the solar water heating target temperature.

Once

or

is pressed a cursor appears beside the

current target temperature. The temperature begins to flash

as it is being adjusted. Once the desired target temperature

is selected wait 5 seconds. The display returns to running

screen.

5.2 Resetting parameters to default

You can reset the system parameters and the timer programs

to the default settings by pressing the

button for

ten seconds. Then the display flashes twice and all of the

parameters are reset to the factory defaults.

5.3 Benchmark

GB: It is a requirement that the “Benchmark” Installation,

Commissioning and Service Record is completed and left with

the user.

IE: it is necessary to complete a “Declaration of Conformity” to

indicate compliance to I.S.813. An example of this is given in

the current edition of I.S.813.

5 Commissioning

5.4 Hand over to the householder

l

Hand over all manuals to the householder.

l

Advise the householder to keep the manuals near to the

system.

l

Draw special attention to the safety instructions which the

householder must follow.

l

Review the user instructions with the householder and

answer any questions.

l

Show the householder how to operate the solar control, CH

control and any separate DHW control.

l

Inform the householder that the cylinder temperature is

factory set at 65°C and that the DHW temperature can be

adjusted using the TMV by the installer.

l

Inform the householder that the immersion heater is

intended as a standby device and should not be used

simultaneously with the boiler to heat the cylinder.

l

Inform the householder that they are not permitted to

change the settings made on the solar system.

l

Inform the householder that to ensure the continued

efficient and safe operation of the solar system it is

recommended that it is checked and serviced at regular

intervals. The frequency of servicing will depend upon the

installation conditions and usage, but in general, once a year

should be enough.

l

Inform the householder that the boiler and solar cylinder

should be serviced by a qualified engineer annually.

Leave these instructions and the “Benchmark” Installation,

Commissioning and Service record document with the user.