26

2000225229C

Diagram 10.4

7168

ELECTRICAL

PLUG

EXTENDED
SECURING

SCREWS (4)

SOLENOIDS

10 Replacement of Parts

SOLENOID

SECURING
SCREW

10.4 Control Board (PCB), Part No.

2000227135 - diagram 10.3

Remove casing, see Section 5.2.

Slacken control box securing screw, see diagram 5.10.

NOTE: To ease access the control box may be pulled away from
the boiler by removing the hinge pins, see diagram 5.10.

Carefully pull the control knob and extension piece away from
the PCB.

Carefully pull the board away from its supports.

Disconnect the electrical plugs by slightly bending back the
retaining latches to allow withdrawal.

Disconnect the HT lead and spark earth lead.

When refitting refer to wiring diagram 9.5.

Take care when replacing the control knob and extension by
supporting the potentiometer on the P.C.B.

10.5 Electrode

Remove casing, see Section 5.2.

Remove combustion chamber front cover, see diagram 10.5

Remove HT lead from electrode, see diagram 8.5.

Remove earth lead from electrode retaining bracket, see
diagram 8.5.

Remove electrode bracket by undoing screw and withdrawing
off locating pin, see diagram 8.5.

When refitting, check spark gap, see diagram 8.5.

10.6 Multifunctional Control, Part No. 230509

- diagram 10.4

Gain access as Section 5.2.

Slacken control box securing screw, and swing out the control
box, see diagram 5.10.

Disconnect the electrical plug.

Disconnect from the gas cock by removing the four extended
screws from the flanged connection at the right hand side.

Support the multifunctional control, disconnect from the manifold
by removing the tubing nut from the left hand side.

Remove and discard the original “O” ring from the flanged
connection and fit the new “O” ring supplied, into recess, before
fitting the replacement multifunctional control.

After assembly test for gas soundness and purge in accordance
with the current issue of BS6891 or in IE, the current edition of
I.S.813 "Domestic Gas Installations".

10.7 Solenoid - diagram 10.4

Remove the electrical plug from the multifunctional control.
Remove the securing screw and then the solenoid assembly.

10.8 Burner

Remove the burner as Section 8.2.

10.9 Injectors, Part No. 205764

Remove the burner as Section 8.2.

Remove the injectors as Section 8.4.

10.10 Insulation - diagram 10.5

Combustion Chamber Front

Gain Access as Section 5.2.

Remove the combustion chamber front, then the insulation.

Diagram 10.5

SIDE INSULATION

12276

REAR INSULATION

SIDE INSULATION

FRONT INSULATION

7195

RETAINING

SCREW

Sides

Slide the insulation out.

Rear

With the side insulation removed the rear insulation can be
removed and replaced.

Advertising