10 Replacement of Parts

ELECTRICAL
CONNECTIONS

RED AIR TUBE

CLEAR AIR

TUBE

SECURING
SCREW

FAN

SECURING
SCREW (3)

Diagram 10.7

7165

Diagram 10.6

RED AIR TUBE

ELECTRICAL
CONNECTIONS

CLEAR AIR

TUBE

SECURING

SCREW (2)

AIR

PRESSURE
SWITCH

7227

FAN
ASSEMBLY

IMPORTANT:
REMOVE ELECTRICAL CONNECTIONS

BY GRIPPING THE BOOT ONLY

10.11 Air Pressure Switch, Part No. 227128 -

diagram 10.6

Gain Access as Section 5.2.

Remove the air pressure tubes and electrical connections from
the switch, release the screw and remove the switch.

When fitting the replacement make sure that the plastic tubes
are fitted as shown in diagram 10.6 and the electrical connections
as shown in diagram 9.5

10.12 Fan, Part No. 227035 - diagram 10.7

Refer to Section 5.3.

Remove the electrical connections and disconnect the air
tubes.

NOTE: Remove the electrical connections by pulling insulation
boots only.

Remove the fan assembly securing screw at the front, then
withdraw the assembly.

The fan is secured to the flue hood by three screws.

The polarity of the electrical connections are not important.