8 Safety Discharge Valve and Condensate Connections

8.1 Safety Discharge Valve

The pipe from the safety discharge valve must not discharge
above an entrance, window or any type of public access area.

A short discharge tube is supplied loose in the wall mounting
pack. This must be extended, using not less than 15mm o.d.
pipe, to discharge, in a visible position, outside the building,
facing downwards, preferably over a drain, see diagram 8.1.

The pipe must have a continuous fall and be routed to a position
so that any discharge of water, possibly boiling, or steam,
cannot create any danger to persons, damage to property or
external electrical components and wiring.

To ease future servicing it is advisable to use a compression
type fitting to extend the discharge pipe.

8.2 Condensate Drain Connection

The condensate drain connection is behind the pump at the rear
of the boiler, see diagram 8.2. A flexible condensate outlet pipe
is supplied loose in the base polystyrene packaging. Fit the
angle connector of the flexible pipe onto the spigot. The straight
connector can accommodate a drain pipe of 22mm to 25mm
O.D.

The condensate should have a fall of at least 2.5

o

away from the

boiler and if possible be discharged into the household internal
drainage system. If this is not practicable, discharge can be
allowed into the external household drains or a purpose designed
soak-away.

It is recommended that any external condensate drain pipe is
insulated or of a 32mm diameter, to prevent freezing in adverse
weather conditions.

The condensate is discharged periodically in ‘slugs’ by siphonic
action.

It is not necessary to provide air breaks or extra traps in the
discharge pipe as there is already a trap inside the boiler. Fitting
an extra trap may cause the boiler siphon to work incorrectly.

Refer to BS5546 or BS6798 for advice on the disposal of boiler
condensate.

A range of condensate fittings are available. These cost effective
easy to install condensate fittings, when used, are designed to
help installers with the easy removal of condensate.

The fittings are available from Hepworth Plumbing Products
and normal distribution channels.

Diagram 8.2

CONDENSATE
DRAIN

FLEXIBLE
PIPE

12901

Diagram 8.1

SAFETY
DISCHARGE
VALVE

11694

SAFETY
DISCHARGE
VALVE PIPE

UNION NUT
Tighten half turn
past finger tight

CONDENSATE FITTINGS

Description

Nom Dia. mm.

Overflow to Waste Adaptor (A021).

21.5

For connection to 32mm.
or 40mm Push - Fit or
Solvent Weld pipe.

Overflow to Rainwater

21.5

Adaptor (A022).
For connection to round
and square section downpipe.

Overflow to Soil

32 or 21.5

Adaptor (S117).
For connection to 110mm
soil pipe.

Overflow to Soil

40 or 21.5

Adaptor (S118).
For connection to 110mm
soil pipe.

Conensate Soakaway (S951).

21.5