14 replacement of parts – Glow-worm sxi and Gas Valve User Manual

Page 47

Advertising
background image

47

0020015347-03

14 Replacement of Parts

Diagram 14.21

MAINS RESET
SWITCH

KNOB
RETAINING
CLIPS

MAINS RESET
KNOB

14.33 Control Box

For access, refer to section 14.33.

Remove relevant plugs and connectors, refer to wiring diagram
13.2.

Withdraw grommets and leads so they are hanging loose.

Unthread the retaining strap and remove the control box by
drawing it outwards away from its retaining slots, see diagram
14.22.

14.34 Fuse - Main PCB - Control Box

For access, refer to section 14.33.

The fuse (rated 630mAT) is located at bottom right hand side of
the PCB, see diagrams 13.2 or 14.22.

REAR
PANEL

CONTROL
BOX

RETAINING
STRAP

RETAINING
SLOTS

USER INTERFACE

SECURING SCREWS

PCB RETAINING
CLIPS

MAIN PCB

Diagram 14.22

TORX
SCREWS (3)

Diagram 14.23

12411

FUSE

Diagram 14.24

230V CONTROLS INTERFACE BOARD

USER INTERFACE

11419

14.35 User Interface

Refer to section 14.29 for access and diagram 14.23.

Remove electrical plug.

Remove the two securing screws.

Withdraw the board.

When replacing the board refer to instructions supplied with
replacement PCB on setting it up.

14.36 230V Controls Interface

For access, refer to section 14.29.

Disconnect the electrical connection from the 230V controls
board and the electrical connection from the Main PCB, see
diagram 14.24.

Remove the 230V controls interface retaining screw.

Remove the 230V controls interface board.

11417