Installation, 13 specifi c adjustment – Glow-worm Systempro User Manual

Page 12

Advertising
background image

0020128352_01 - 03/11 - Glow-worm

- 10 -

INSTALLATION

EN

12.2.2

Menus and functions

The available settings are diff erent depending on the installation

layout and the options selected.

Menus and functions
Installation

Modifying the installation (*)

This menu allows you to change the diagram number when modifying

the installation’s confi guration.

A diagram number is assigned to each possible installation, with

various options available. The number is indicated in the system

manual.

Modifi cation options (*)

This menu allows you to enable or disable the options available in the

selected installation diagram.

Thermostat/sensor (wireless)
Thermostat connection(s)
Sensor connection
Ext. temperature correction
Automatic test
EBUS inputs
NTC inputs
the RF connection with the Climapro2 room thermostat
the outdoor sensor radio connection
I/O card
Parameters
Heating

Max. heating outlet T°
Auto heating curve
Manual heating curve
Advance heating

Hot water

Max. domestic hot water temperature

Cooling

Cold water outlet temperature setting

Energy management

Resetting parameters

The resetting of factory settings is irreversible. Any customised

confi guration of the control unit will be lost.

Commissioning

This menu allows you to carry out the necessary operations on

the appliances following installation (refi lling, bleeding, fl ow rate

control...).

Component information (**)

This menu enables real-time access to:

- the status of the appliances responding to a demand (ON / OFF)

- the reading the diff erent information available from the appliances

(temperature, pressure, fl ow,)

- the register of last 5 faults recorded for each appliance (date, time,

code and description of faults).

- resetting the fault report.

Options
Date (***)
Time (***)
Automatic winter/summer time change
Languages
Screen (brightness / contrast)

About

This function is used to display the versions of the various electronic

components attached to the management box.

i

(*) On entry into the menus installation modifi cation

and options modifi cation, the management box warns

that “the system is shutting down”. “the system is

currently stopped" No further heating control operations

are eff ected. ... Setting will restart after leaving these

menus.(**) Refer to the system manual to fi nd the

description of the fault code displayed on the screen.

(***) The date and time are set from the room thermostat

in an individual installation.

13 Specifi c adjustment

13.1 Wireless

connections

13.1.1

Pairing with the wireless thermostat(s)

This function lets you perform the pairing between the Climapro2

RF and the radio receiver.

In the case of an individual installation which includes a low

and high temperature heating zone. “Zone 1” must imperatively

be allocated to a low temperature heating zone. The room

thermostat in zone 1 has the “main thermostat” status.

Adjustments must be made simultaneously to the control unit and

the room thermostat.

Via the control unit:

From the installation menu in the control unit > select on the

screen > thermostat/sensor > room stat(s)

Via the room thermostat:

Via the installer room thermostat menu > select on the screen >

RF > pairing

The control unit and the room thermostat will immediately

indicate recognition on their respective "connection in progress"

screens.

13.1.2

Pairing with wireless outdoor sensor

Consult the outdoor sensor’s installation manual in order to

carry out the operation.

Advertising