13.2 Resetting the control unit

This function allows you to reset the control unit (factory setting).

b

The resetting of factory settings is irreversible. Any

customised confi guration of the control unit will be

lost.

Simultaneously press the buttons

for 10

seconds.

Confi rm by pressing

.

14 Re-check and restart

Once the control unit is installed, check the operation.

Switch the control unit on to ensure that any adjustments

operate correctly and check that the appliance operates safely.

15 User information

At the end of the installation:

- explain the operation of the equipment and its safety devices

to the user, if necessary provide a demonstration and answer

any questions;

- give the user all the required documentation,

- fi ll in the documents where necessary;

- advise the user of the precautions necessary to prevent

damage to the system, appliance and the building;

- inform the user of the guarantee conditions,

- explain to the user the usage envelope of the appliance and

the limits of the manufacturer’s responsibility,

- remind the user to service the appliance annually.

MAINTENANCE

16 Trouble-shooting

16.1 Fault

diagnosis

The following checks should be performed before proceeding

onto specifi c diagnostics:

- Ensure that it has not been disconnected from the electricity

network and that the control unit is connected correctly.

- Ensure that all installation’s appliances are available.

- Check the functioning of external regulatory devices (room

thermostat, remote sensor,).

16.2 Maintenance

menu

16.2.1

Access to the maintenance menu

Press the “menu” button for 7 seconds.

Enter the installer maintenance access code 35.

Press the button

to confi rm.

The maintenance menu includes the installation menu function,

plus 2 additional functions:

- "System tests", within the maintenance menu,

- "After sales service Info", in the options.

16.2.2 System

tests

This menu allows you to test the operation of all the appliances

and the system (boiler, HP, valve,) present in the installation.

Each element can be controlled centrally by activating its normal

start-up function or by individual component.

i

By entering the test menu, the control unit display’s

the following message: “the system is currently

stopped" No further heating control operations are

aff ected. Control is resumed upon exiting the menus.

16.2.3

After sales service info

This menu provides access to After sales Service information:

- date of last access to installer menus

- the name of the company which provides the after sales

service, if entered during installation.

- the telephone number of the company which provides the after

sales service , if entered during installation.

16.3 System failure codes

i

Refer to the system manual. The breakdowns

described in the system manual must be handled by a

qualifi ed professional and, if necessary, by the after-

sales department.

The fault status may be “inactive” (disappeared) "active" (still

aff ects the installation).

The installation can operate partially with a fault “active”. It is not

necessarily “blocking”. An alarm (not supplied) can be added to

the installation to signal certain faults.