Installation, Bd c e – Glow-worm Systempro User Manual

Page 9

Advertising
background image

0020128352_01 - 03/11 - Glow-worm

- 7 -

INSTALLATION

EN

9.2.1 Wall

mounting

Step 1

B

D

C

E

5

A

1

2

3

4

5

6

7

8

Key

1 Hatch

screw

2 Control unit hatch

3 Lower attachment holes

4 Control

unit

5 Upper attachment holes

6 Upper

screw

7 Plug

8 Holes

Mount the appliance following the steps from (A) to (E).

Remove the control unit (4) by sliding along the wall.

Step 2

B

A

1

2

3

4

6

5

Key

1 Lower

screws

2 Control

unit

3 Upper

screw

4 Upper attachment holes

5 Plug

6 Holes

Mount the appliance following the steps from (A) to (B).

9.2.2

Mounting on DIN rail

A

1

2

3

4

Key

1 Lower

screws

2 Control

unit

3 DIN rail (not supplied)

4 DIN mounting (not supplied)

10 Electrical connections

e

Incorrect installation can cause electric shock or

damage to the equipment. The electrical connection

must be made only by a qualifi ed engineer.

Ensure system is electrically isolated.

Protect the electrical installation by following the guidance

indicated in the “Technical data” chapter.

e

Warning! The length of the power supply cable must

not exceed 10 metres.

The electrical installation in the dwelling must permit the

power supply to the equipment to be isolated by a double pole

isolation switch and be fused. The double pole isolation switch

must incorporate a gap of 3mm between the contacts.

Use a power cable suitable for the mains connection, minimum

0.75 mm. If the cable is damaged, it must be replaced by a

qualifi ed engineer.

The external wiring must be earthed. The polarity must be correct

and consistent with current standards.