Technical data, 17 systempro, 4 control unit failures – Glow-worm Systempro User Manual

Page 14: 5 replacing a fuse, 6 mains supply cable

Advertising
background image

0020128352_01 - 03/11 - Glow-worm

- 12 -

TECHNICAL DATA

EN

16.4 Control unit failures

i

Faults described in this chapter should be carried

out by a qualifi ed engineer and if needed by the After

Sales Service.

Description

Cause

Solution

No display on

screen

The power

supply is faulty.

The fuse is

damaged.

Make sure that the electricity

supply has not been interrupted.

Check that 230V supply is turned on

and present.

Check the position of the control

unit switch.

Check the control unit’s fuse.

16.5 Replacing a fuse

B

C

D

F

A

E

1

2

4

3

Key

1 Fuse

2 Control

unit

3 Switch On (I) / Off (O)

4 Fuse

holder

Turn off the control unit (2) with the switch (3) in position (O).

Turn off the power supply to the control unit (2) at the isolating

switch.

Replace the fuse following the order (A) to (F).

Turn on the power supply to the control unit (2) at the isolating

switch.

Turn on the control unit (2) with the switch (3) in position (I).

16.6 Mains supply cable

e

The main supply cable must be replaced by a

qualifi ed and competent electrician.

If the main supply cable is damaged, replace it refering to the

chapter "Electrical connection".

TECHNICAL DATA

17 SYSTEMPRO

Description

Unit

Control unit

Transmission / reception

frequency

MHz

868

Transmission / reception

frequency with outdoor sensor

min

15

Transmission / reception

frequency with room thermostat

min

10

Average radio signal range in

open air (*)

m

100

Average radio signal range

indoors (*)

m

25

Control unit dimensions:
Height

mm

264

Length

mm

290

Depth

mm

45

(*) Depends on the installation’s conditions and the electromagnetic

environment.
Electricals
Power-supply voltage

VAC/Hz

230/50

Power cable gauge

mm²

3 x 0.75

EBUS connection cable gauge

mm²

2 x 0.75

Current

A

4.35

Delay fuse

A

1

Electrical protection

IP20

Electrical classifi cation

I

Surge category

II

Pollution rating

2

Contact outputs fed work

A

8

V

230

Action auto

type 1.C

Advertising