Maintenance, Boiler access, 2 spark electrode – Glow-worm Ultracom hxi User Manual

Page 38: 3 igniter unit, 4 ignition lead, 5 gas valve

Advertising
background image

0020107233_00 - 06/11 - Glow-worm

MAINTENANCE

- 38 -

13 Replacement of Parts

13.1 General

IMPoRTanT: The replacement parts described in sections

13.5 to 13.9 and section 13.12, will require the removal of the

burner module assembly and the replacement of the burner

door seal and self locking nuts.

Replacement parts that have associated components that

need replacing on removal, i.e. ‘O’ ring, seals, gasket, etc.,

will be supplied and should be fitted.

Replacement of parts must be carried out by a

competent

person approved at the time by the Health and Safety

Executive.

Before replacing any parts of the boiler it should be isolated

from the mains electric supply and the gas should be turned

off at the gas service isolation valve on the boiler, see

diagram 10.1.

Unless stated otherwise parts are replaced in the reverse

order to removal.

After replacing any parts always test for gas tightness and if

necessary carry out functional test of the controls.

boiler access

For replacement of parts the front casing and the inner casing

panel of the boiler will need to be removed. To remove undo

the two screws on the underside of the front casing and lift off.

Undo the two screws on the front of the inner front panel and

lift off.

The side panels can be hinged sideways and removed to aid

replacement of parts.

To hinge a side panel undo and remove the three screws

securing each side panel to the boiler, two at the front and

one at the top.

13.2 Spark electrode

For access, refer to section 13.1.

Refer to section 11.2 for removal.

13.3 Igniter Unit

For access, refer to section 13.1.

Remove ignition lead and electrical connections then remove

igniter unit by removing two securing screws, see diagram

13.1.

13.4 Ignition lead

For access, refer to section 13.1.

Refer to diagram 11.4 and 11.5.

Pull the spark plug style connector off the spark electrode and

the spade connector connected to the igniter unit.

13.5 Gas Valve

For access, refer to section 13.1.

Refer to section 11.3 for removal of the fan, gas valve and

burner assembly.

Before removing the gas valve note its position on the fan.

Remove the three securing screws, which fix the gas valve

and plastic swirl plate to the venturi on the fan, see diagram

13.2.

Withdraw the gas valve.

After re-fitting check the combustion CO

2

and adjust if

necessary, refer to section 11.

Diagram 13.1

13274

13276

VENTURI
PLATE

SECURING
SCREW (3)

Diagram 13.2

After assembly test for gas tightness and purge in accordance

with the current issue of BS6891or in IE, the current edition of

I.S.813 “Domestic Gas Installations”.