Battery charge profile chart – Go Power! GP-PWM-30 User Manual

Page 12

Advertising
background image

Solar Controller

GP-PWM-30

______________________________________________________________________

12

© 2012 Carmanah Technologies Corporation

September 2012

Battery Charge Profile Chart

Auto Equalize: The GP-PWM-30 has an automatic equalize feature that
will charge and recondition your batteries once a month at a higher
voltage to ensure that any excess sulfation is removed. This feature is
recommended for Flooded batteries only. Check with your battery
manufacturer.

NOTE: This feature is only available for Charging Profile 1.

Battery Type

FLOODED

AGM

GEL

Charging Profile #

1

2

3

Float Charge @ 25°C:

13.7V

Bulk/Absorption Charge @ 25°C:

Applied for 1h each morning

14.4V

14.1V

Boost Charge

Applied for 2 hours if the battery voltage drops
below 12.3 volts.

14.4V

14.1V

Equalization Charge

Applied for 2 hours every 28 days and if the
battery voltage drops below 12.1 volts.

14.8V

N/A

N/A

The Boost Charge will occur in addition to the Bulk Charge. The Equalization Charge will
occur in addition to the Boost Charge.

If a charging cycle is unable to complete in a single day, it will continue the following day.

The terms FLOODED, AGM and GEL are generic battery designations. Choose the
charging profile that works best with your battery manufacturer’s recommendations.

Advertising