Service procedures – Desa H.S.I. User Manual

Page 7

Advertising
background image

112846-01A

7

7

For more information, visit www.desatech.com

For more information, visit www.desatech.com

SERVICE PROCEDURES

WARNING: To avoid risk of burn and electrical

shock, never attempt to service heater while it is
plugged in, operating, or hot.

Upper Shell

Fan
Guard

Figure 4 - Upper Shell Removal

UPPER SHELL REMOVAL

1.

Remove screws along each side of heater using 5/16" nut-driver.
These screws attach upper and lower shells together. See Fig-
ure 4.

2.

Lift upper shell off.

3.

Remove fan guard.

Screw

FAN

IMPORTANT:

Remove fan from motor shaft before removing

motor from heater. The weight of the motor resting on the fan could
damage the fan pitch (see Figure 5).

1.

Remove upper shell (see Figure 4).

2.

Use 1/8" allen wrench to loosen setscrew which holds fan to
motor shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using a soft cloth moistened with kerosene or solvent.

5.

Dry fan thoroughly.

6.

Replace fan on motor shaft. Place fan hub flush with end of
motor shaft (see Figure 6).

7.

Place setscrew on flat of shaft. Tighten setscrew firmly (40-50
inch-pounds/4.5-5.6 n-m).

8.

Replace fan guard and upper shell.

AIR OUTPUT, AIR INTAKE AND LINT FILTERS

1.

Remove upper shell (see Figure 4).

2.

Remove filter end cover screws using 5/16" nut-driver (see
Figure 7).

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see Preventative Maintenance
Schedule
, page 5).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

Motor
Shaft

Setscrew

Figure 5 - Fan, Motor Shaft,
and Setscrew Location

Motor
Shaft

Fan

Setscrew

Figure 6 - Fan Cross Section

Fan

Flush

Motor

Figure 7 - Air Output, Air Intake, and Lint Filters

Air Intake
Filter

Lint Filter

Filter End
Cover

Air Output
Filter

SERVICE PROCEDURES