Faults and warnings, D series lake quick start guide rev 1.2.0 – Lab.gruppen D Series 80:4L User Manual

Page 23

Advertising
background image

14. Faults and warnings

D SERIES Lake Quick Start Guide rev 1.2.0

23

14. Faults and warnings

Category/Type

Name

On screen text

Description

Action

FRAME

Warning

Lake Controller offline

CTRL OFFLINE

Frame unable to find Lake controller

on the network

Check network cabling/

network if controller

expected on the network

Warning

AES clock slipping

CLOCK SLIPPING

Frame not able to lock to

incoming AES stream

Check AES sender and

clock configuration

Warning

Dante device name conflict

NAME CONFLICT

Two or more devices on the network

with the same Dante name

Review Dante

configuration

Warning

Dante module not detected

DANTE NEEDS

SERVICE

Lake cannot detect a functioning

Dante module

Restart device; if not

cleared it needs service

to operate Dante

Warning

Dante module with

incompatible firmware

DANTE FW INVALID

Dante module not loaded

with correct FW

Retry updating the firmware

with LakeUpdate

Fault

Audio Fault

AUDIO FAULT

Internal audio interface

not functioning

Restart device; if not

cleared it needs service

Fault

Sense fault DSP

SENS FLT:DSP

Voltage and current sensing on amplifier

output faulty. Audio continues but

protection might be compromised.

No load monitoring

Restart device; if not

cleared it needs service

Fault

A/D converter power

supply fault

A/D PSU FAULT

Voltage supply to the analog input

converters faulty

Restart device; if not

cleared it needs service for

analog input to work

TEMP

Warning

Temperature warning

power supply

TEMP WARN:PSU

Power supply temperature

approaching critical levels

Improve cooling or reduce

output power to avoid

temperature becoming

critical

Warning

Temperature warning

DSP area

TEMP WARN:DSP

DSP area temperature approaching

critical levels

Improve cooling or reduce

output power to avoid

temperature becoming

critical

Warning

Power supply

Temperature Limit

PTL ACTIVE

Amplifier is reducing output power

to avoid power supply temp

fault protection

Improve cooling or reduce

output power to avoid

limiting

Warning

Amp channel

Temperature Limit

ATL ACTIVE

Amplifier channel is reducing output

power to avoid amplifier channel

temp fault protection

Improve cooling or reduce

output power to avoid

limiting

Fault

Temperature fault

power supply

TEMP FLT:PSU

Power supply temperature reached

internal protection limit

Automatically restarts

when cooled down

Fault

Temperature fault

DSP area

TEMP FLT:DSP

DSP area reached

critical temperature

Improve cooling or

reduce power

Advertising
This manual is related to the following products: