14. Faults and warnings

24

D SERIES Lake Quick Start Guide rev 1.2.0

Category/Type

Name

On screen text

Description

Action

PSU

Warning

Under Voltage Limit

UVL ACTIVE

The Under Voltage limiter is active as the

mains supply is approaching the lower

end of the device´s operational voltage.

Output power is decreased to ensure

mains distribution does not collapse

Increase mains distribution

stiffness or reduce output

power to avoid limiting

Warning

Power Average Limit

PAL ACTIVE

Amplifier is reducing output power due

to average power or mains current

draw is above safe operating levels

Reduce output power

to avoid limiting

Warning

Breaker Emulation Limit

BEL ACTIVE

Power supply is reducing mains current

draw to stay within BEL configured

nominal current and profile

Improve mains distribution

and update BEL

configuration or reduce

output power to avoid

limiting

Warning

Mains supply glitch

MAINS GLITCH

Mains glitch (missing cycles) was

detected on the mains inlet

Check mains distribution/

connection

Warning

Upgrade power

supply firmware

UPGRADE PSU

Power supply firmware version not

compatible with amplifier

Upgrade amplifier

firmware

Fault

Need service

NEED SERVICE:1-8

Power supply internal error

Restart device; if not

cleared it needs service

Fault

Mains voltage above

400 volt peak

MAINS>400 VPK

Power supply detects mains voltage

above 400 volt peak. Protective shut

down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage above

270 V

MAINS>270 V

Power supply detects mains voltage

above operation voltage. Protective

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage below

65 V

Mains<65 V

Power supply detects mains voltage

below operation voltage. Protective

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Power supply fault

PSU FAULT

Internal power supply fault

Check mains distribution/

connection. Restart

device; if not cleared

it needs service

Fault

Check mains

CHECK MAINS

Power supply detects unstable mains

supply. Protective shut down, auto

restart attempt

Check mains distribution/

connection

Fault

Power supply power protect

PSU POWER PROT

Too high output power for too low mains

supply voltage. Protective shut down,

auto restart attempt

Improve mains supply

voltage or reduce

output power

LOAD

Warning

Speaker short

SPKR SHORT

Both LoadPilot tones below thresholds

Check load or calibration

Warning

Speaker damaged

SPKR DAMAGED

One LoadPilot tone is above

or below threshold

Check load or calibration

Warning

Under speaker count

UNDER SPKR CNT

Both LoadPilot tones above thresholds

or LoadSmart detected fewer

speakers than expected

Check load and

cabling alibration

Advertising