8. Appendix

8.1 Faults and Warnings Overview

Fault or warning conditions are indicated by the LED shown in Figure 6-3 on page 18. As the LED indicates
several types of faults or warnings, a brief textual description of the fault or warning is provided on the LCD
display. Section on page 21 details the fault and warning indications that appear on the front panel. Table 8-1
lists the events that may have triggered each fault or warning condition.

LCD Text

Event Log Text

Type

Description / Troubleshooting

ANALOG IN
FAULT

Frame Fault:
Analog Input

Fault

There is a problem with the analog input. Verify signal and connec-
tions.

CLOCK
SLIPPING

AES Clock
Slipping

Warning

The selected digital clock and digital input combination is not
aligned. Verify digital input configuration to ensure all clock settings
match.

CTRL OFFLINE

-

Warning

The device is no longer able to communicate with the Lake Control-
ler. Check network connectivity.

FAN FAULT

Frame Fault: Fan
error

Fault

There is a problem with the fan on the device. To avoid overheating,
identify and fix the problem immediately.

IN RTR MUTE

Input Router X
Mute

Mute

An input router is muted; all Modules and outputs sourced from
this input router will be affected.

NO INPUT

No Input Source

Fault

No input signal can be identified for any valid unmuted input router.
Connect an input source, or verify input signals and connections.

OVERTEMP

Temp Fault: DSP
area

Fault

The temperature has reached a critical 70

o

C (158

o

F). Turn the unit

off or take steps to cool the unit immediately; continued operation
cannot be guaranteed.

PROTECTIVE
MUTE

Protective mute
via GPIO

Event

A processor mute state has been triggered via GPIO. Change this
setting using the external control device.

PSU FAULT

Frame Fault:
PSU

Fault

There is a problem with the power supply for the Analog inputs.
Analog inputs will not be available. Send the device for service.

TEMP
WARNING

Temp Warning:
DSP area

Warning

The temperature has reached 55

o

C (131

o

F). Monitor the tempera-

ture and take additional steps to reduce temperature if it continues
to increase.

-

Frame Offline

Warning

The Lake Controller is no longer able to communicate with the
device. Check network connectivity.

-

Module Input
Mute

Mute

A Module Input has been muted. The mute is identified via the
associated Module Input mute button on the front panel.

-

Module Output
Mute

Mute

A Module Output has been muted. The mute is identified via the
associated Module Output mute button on the front panel.

Sound Source
Changed

Warning

The input source has been changed either manually or by automatic
input priority detection.

Table 8-1: Warning, Fault and Mute Indications (alphabetical by LCD Text / Event Log Text)