Troubleshooting – Laerdal SimJunior Standard User Manual
Page 26
24
Troubleshooting
• Check that there are no obstructions inside the manikin airways
which may block air flow.
• If there is no change when adjusting lung compliance, contact
Laerdal Technical Service.
• If there is no change in lung resistance, contact Laerdal Technical
Service.
Mechanical Noise during Auscultation
In the Instructor Application, click <Auscultation focus>.
Pulses (Radial and Brachial)
Problem
• Cannot feel pulses
Possible Solutions
• Skin may be too tight over pulse units – re-adjust skin and
reboot.
• Ensure blood pressure is set to at least 60 systolic.
• Ensure compressor is ON.
Note: If the radial pulse is set below 60, peripheral pulses
may disappear.
Manikin Shutdown
Problem
• The manikin is unresponsive.
Solution
1. Power off the Link Box.
2. Turn the SimPad off.
3. Exit any SimJunior software on the optional Instructor PC and
the Patient Monitor.
4. Then restart everything.
If the manikin is still unresponsive, contact your Laerdal representative.