Items included

The Laerdal SimMan includes the following main components:

- Laerdal SimMan Manikin
- SimMan Software CD-ROM
- Directions for Use
- SpO

2

(Pulse Oximetry Probe)

- Set of Defibrillation Studs:
- Hands Free Defibrillation/Pacing Adaptors

(Heartstart and Physio Control)

- Plates for Manual Defibrillation
- Replaceable Neck Skin Collars (6)
- Roll of Crico-Thyroid Membrane Hy-Tape (2)
- Chest Tube Insertion Modules (6)
- Interchangeable pupil set [case containing 3 pairs of pupil inserts

(normal, constricted, dilated)]

- Airway Lubricant
- Upper Dentures

[one (1) non-breakable installed, and (3) breakable]

- Replaceable Male and Female Genitalia

with Urinary Connection Valves

- Tank Thigh Hardware Kit
- Tool Kit, consisting of:

- Pliers
- Screw-driver
- Nut Driver
- Bolts for attaching optional wound modules to the body

- Maintenance/Repair Kit, consisting of:

- Extra Pneumothorax Bladders
- Modeling Wax
- Talcum Powder

- IV Kit, consisting of:

- Blood Bags with IV Tubing (2)
- Simulated Blood Concentrate

- Hose, Manikin Air and CO

2

Supply

- Blood Pressure Measuring Kit
- Track Suit (jacket and trousers)

In addition, some configurations contain the following:
- Laptop computer
- USB Camera
- Simulated Patient Monitor
- USB Hub
- PDA
- Link Box

Connection Cables and Tubing
(may vary depending upon configuration):
- Cable, Link Box to Manikin (15 pin)
- Cable, Link Box to PC (9 pin)
- Cable for Sounds, PC to Link Box

Additional items purchased separately
- Pressurized Air and CO

2

source (Compressor Unit

or Regulator Unit)

Getting started

To use your SimMan, carefully follow the instructions provided in
the “Install Guide” (found in the peripheral box) and this document.
Some configurations are delivered with pre-installed software.
If your system is not pre-installed, pay close attention to software
set-up. Your SimMan will not operate correctly if the software is
not properly installed.

Attaching the Legs:
1) Remove the belly by pulling gently on the bottom and place it

aside.

2) Remove the bag from the leg.
3) Remove the cardboard packing tube from the threaded steel

tube protruding from the upper end of the thigh.
Caution: Do not allow tape or packing to pull on the wire or
air tube extending from the steel tube.

4) Open one Tank Thigh Hardware Kit (1008080) and place the

hardware in a convenient spot.

5) Gently feed the electrical wire and plastic air tube through the

pelvis hole and into the pelvic cavity.

6) Push the steel tube on the thigh as far as possible through the

hole and into the pelvic cavity.
DO NOT PULL THE LEG BY THE ELECTRICAL WIRE
OR PLASTIC AIR TUBE

7) Slide the flat washer from the hardware kit over the wire, air

tube, and steel tube.

8) Slide the spring from the hardware kit over the wire, air tube,

and steel tube.

9) Slide the thumb nut from the hardware kit over the electrical

wire first, and then over the air tube.

10) Holding the thigh in a convenient position, thread the thumb

nut onto the steel shaft until the feel of the hip articulation is
satisfactory.

11) Attach the thigh air tube to the open connector on a similar air

tube in the pelvis. Right leg tube goes to the tube on the right
side, and left goes to left.