Laerdal Ultimate Hurt User Manual

Page 7

Advertising
background image


Legs:

Legs are attached with a bolt, two washers, a spring and
a wing nut.

To attach:
1. Remove belly plate from manikin to locate hole in

hip.

2. Remove thigh injection pad from leg.
3. Remove wing nut and washer from bolt inserted in

the leg. (Leave spring assembly in thigh of leg.)

4. Insert bolt through hole in pelvis.
5. Slide washer and wing nut back over bolt.
6. Use a screwdriver to drive bolt into wing nut (See

Fig. 2).


To remove legs, reverse procedure.

Fig. 2


Laerdal Recommends


Intubation devices and airway
passages should be lubricated
with silicone or liquid soap
prior to intubation.

Instructions for Use:


Intubation:
When using Trauma Intubation Head
or Deluxe Intubation Head, the
following equipment is recommended:

a. Endotracheal tube size 7.5 ID or smaller
b. 10 ml syringe
c. Laryngoscope blade, sizes #3 or #4 straight or curved

blade

d. Laryngoscope handle

201-00001

Laerdal

7

Advertising