5. CALIBRATION AND MAINTENANCE

BETA D-50

BATTERY

VOLMETER
TEST

V

PORTS

EXTERNAL CALIBRATED

VOLTMETER

Figure 5-1 - Circuit diagram for voltmeter calibration

A.

SWITCH OFF MAINS POWER

Turn off the AC on-off/reset power switch.

B.

TURN DOWN DISCHARGE CURRENT

Repeatedly turn the Current Adjust knob fully counter-clockwise to set discharge
current to zero.

C.

CONNECT BATTERY

Connect the battery DC cable to the fully charged battery and ensure the
connector is plugged in completely.


D.

PLUG IN VOLTMETER

Plug in the external digital voltmeter into the voltmeter calibration ports. Set it to a
DC voltage range appropriate for the connected battery.


E.

SWITCH ON MAINS POWER

Turn on the AC on-off/reset power switch. An audible alarm sounds, and the Accept
lamp illuminates. Meters read all 6's or 8's.