7. SPECIFICATIONS

7. SPECIFICATIONS

AC Line Input:

DC Discharge
Current:

Timer



Digital
Meter Accuracy

Cooling:

Housing:

Outer Dimensions:


AC Line Cord:

DC Discharge
Cable:
Weight:

Fuses:

Modes:



115 volts ± 10%, 50/60Hz, 3 amperes or
230 volts ± 10%, 50/60Hz, 1.5 amperes
(selectable on rear of unit)

Capacity

0-50 amperes adjustable current

Accuracy

< ± 2% from discharge initiation to cut-off

Setting

Adjustable from 0 to 999.9 minutes



Accuracy

< ± 0.1%

Voltmeter

< ± 0.2 volts

Ammeter

< ± 0.2 amperes

Fan cooled

Aluminum chassis

Height

14 in. (356 mm)

Depth

15 in. (381 mm)

Width

10 ¼ in. (260 mm)

AWG 16 3 wire grounded
6 ft long with 115 volt 15 ampere plug.
User required to change to 230 volt plug

4 ft long, with Aircraft battery connector

Net 33 lbs.
Shipping 38 lbs.

AC line fuse

3A/250V, type MDA 1 ¼ x ¼

DC line fuse

70AMAXI Fuse

Analysis (automatic cut-off) and deep
cycle (full discharge) with cutoff set to one
volt.