LinkNet

3.9

manual rev 2.1 March 25, 1999

anything desired.

Hit the “Add PM Item” button and the dialog of

figure 3.15 should be displayed.

Figure 3.15:

PM Item Configuration

The dialog of figure 3.15 shows the data already

entered. The information to enter is as follows:

@

PM Type -

Select the type of limit this PM

item should have. This can be one of the
following:

@

Running Time -

Amount of time the press

was actually stroking since the last time this
PM item was reset.

@

Motor On Time

-

Amount of time the

main motor of press has run since the last
time this PM item was reset.

@

Elapsed Time -

Amount of time that has

gone by since the last time this PM item was
reset.

@

Strokes

-

Number of strokes since the

last time this PM item was reset.

@

Total Feed Length

-

Accumulated total

of feed length since the last time this PM
item was reset.

@

Description

-

Enter the description for this

PM item. This could be “Bearing Check”,
“Clutch/Brake Wear Check”, “Press Stopping
Time Check”, etc. This description will appear
in the PM list of figure 3.14 and in PM reports.

@

Value Unit

-

Applies to all time related PM

types and to total feed length. For time related
items, select Hours, Days, Weeks, Months, or
Years. For total feed length, select feet or
meters.

@

Present Value -

When adding an item, this

will always be 0 (since no strokes, time, etc. has
accumulated.). When editing an item, this will
show the current accumulation of whatever is
being monitored. This value can not be edited!
This value will be in the units selected in the
“Value Unit” box.

@

Limit Value

-

The limit to be placed on this

PM item. This value will be in the units
selected in the “Value Unit” box.

@

Notes -

These are free form notes that will

appear in the PM reports associated with this
item. Typical uses would be check lists,
procedures, materials, or anything else that a
maintenance worker would need to know in
order to perform the indicated maintenance.

When all data has been entered, hit the “OK”

button and the maintenance item will be added.

3.7.2

Editing a Preventive Maintenance Item

To edit a PM item, select “Preventive Maint”

from the “Configure” menu as seen in figure 3.1. A
sub-menu with “By Machine” and “By Die” will
appear. Select the desired sub-menu and a dialog
similar to figure 3.13 should appear. This dialog
shows a list of all machines or dies depending on the
menu selection. Select the machine or die for which
a PM item is to be configured and hit the “Select”
button. A dialog similar to figure 3.14 should
appear. Select a PM item to edit and hit the
“Change PM Item” button. The dialog of figure
3.15 should appear. The limit and value units are
the only information that can be changed in this
dialog. If a PM item needs to be renamed, it must
be deleted and re-added with the new name (this is
to keep the database consistent when tracking PM
history).