LINK Systems OmniLink 5000 User Manual

Page 23

Advertising
background image

April 12, 2012

Manual Version 1.1

4.1

NOTE!

An access code is required to reach the configuration menus of the
OmniLink 5000 press control. The code is provided separately from this
manual for administrative control.

WARNING! Only qualified employees who are authorized by the user should

configure the automatic set-up module. Failure to properly configure
and calibrate the module can result in machine damage which, in
turn, may result in injury or death to persons.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

FACTORY
PARAMETERS

EXIT

0

0

Program/Run Switch

TOP

CONFIGURE
MODES

CHANGE
NUMBER

Option

Setting

Hydraulic Overload…………………………….
Inch Button Config…………………………….
Input Board 3……………………………………
Output Configuration………………………….
Tonnage Monitor……………………………….
Die Protection…………………………………..
Automatic Setup……………………………….
Light Curtain…………………………………….
Feed Line………………………………………..
Valve Monitor…………………………………..
V/M Pull In Time (mSec)..…………………
V/M Drop Out Time (mSec)…………………..
V/M Track Time (mSec)…………………..
M/M Turn On Delay (mSec)…………………..
M/M Turn Off Delay (mSec)…………………..
Reserved Factory Parameter………………...

0
0
0
0
1
0
0
0
0
1

100
100
100

2
0
0

Figure 4.1: Factory Configuration Parameters

Section 4.

Configuration

After the ASM is installed (see section 3.1), it must be configured to work with the press. Configuration
consists of several steps that depend on the options selected for the ASM.

Section 4.1

Setting up the OmniLink 5000 for the Auto-Setup Module

The OmniLink 5000 press control must be “told” that the 5000-10 ASM is installed in the card rack.
If the module was installed at Link as part of an OmniLink 5000 package, this step will already be done
and configuration should proceed with section 4.2.

a) Go to the Press Control (P/C) screen.

b) With the RUN/PROG key switch in the PROG position, press the “CONFIGURE” softkey and

enter the configuration access code.

c) Press the “MACHINE PARAMETERS” softkey.

d) Press the “FACTORY

CONFIG” softkey. The
screen should now be
similar to Figure 4.1.

e) Use the up and down arrow

keys on the operator
terminal to put the cursor on
the “Automatic Setup” row
and enter “001". If this
parameter is “000" the
OmniLink 5000 won’t
recognize and respond to
the ASM

f) Press the “EXIT” softkey

until the “Press Control”
screen reappears.

Advertising