6.4

unplugged connector, failed power supply, failed transducer, or option board
(5000-10B) problem.

For rotary slide systems, indicates that the fine resolver is not being read
correctly. This could be a cable problem, unplugged connector, failed
transducer, or option board (5000-10C) problem.

Coarse Resolver Fail

The coarse resolver on a rotary system could not be read correctly. This could
be a cable problem, unplugged connector, failed resolver, or option board
(5000-10C) problem.

Res. Moved in Check

The fine resolver moved while the coarse resolver was being read. Indicates
the resolver may be mounted too loosely or that the slide adjust motor brake is
not holding.

Resolver Misaligned

The fine and coarse resolvers are no longer in proper alignment. Indicates
that one of the resolvers is loose (internally). The resolver may need to be
checked or replaced. The system will need to be recalibrated.

Res. Gearing Wrong

The resolver is geared too high or too low. Refer to section 3.6.1 for resolver
gearing requirements.

Bad Module

The unit did not sense a slide adjust module in the slot it was configured for.
Indicates that the card has become unplugged or that the card has failed.

Bad Config Data

The configuration data for this system was corrupted. The system must be
reconfigured.

Section 6.5

Slide Adjust “Status” Messages

In Position

The slide is within tolerance of the slide setpoint.

Up Limit Switch Open

The slide has hit the mechanical up limit switch and can go no higher.

Down Limit Sw. Open

The slide has hit the mechanical down limit switch and can go no lower.

Max Position Reached

The slide has gone as high as the max position programmed in the
configurations menu and will not be allowed to go higher.

Min Position Reached

The slide has gone as low as the min position programmed in the
configuration menu and will not be allowed to go lower.

Moving Up

The slide is moving up.

Moving Down

The slide is moving down.

System Off

The slide adjust system is turned off. The slide can still be manually moved
by using the jog up and jog down buttons. The slide position will still be