LINK Systems OmniLink 5000 User Manual

Page 49

Advertising
background image

April 12, 2012

Manual Version 1.1

6.5

shown if the position transducer is still functioning correctly.

Waiting for Cntr-Bal

The slide adjust system is waiting for the counterbalance, if present, to come
to its correct pressure before automatically moving the slide.

Slide Too High

The slide is higher than the slide setpoint plus tolerance.

Slide Too Low

The slide is lower than the slide setpoint minus tolerance.

Hyd Overload Tripped

The hydraulic overload has tripped. The slide will not move down in this
condition.

Auto-Adjusting

The slide is automatically going to the programmed slide setpoint.

Waiting for Top

The slide must be at the top of the stroke for automatic positioning to occur.
If a job is recalled at the bottom of the stroke, this message will be displayed
until the press is at the top.

E-Stop Button

Emergency stop button is depressed. The slide will not automatically move in
this condition.

Waiting S/A Switch

Waiting for the slide adjust switch to be turned on. The slide cannot move
while the slide adjust switch is in the off position.

LMC is Out

The Link Master Control relay is disengaged for some reason (possibly an
error at the control). No slide movement may be made while the LMC is
tripped.